الصفحة الرئيسية / المنتج / محلل ليزر ديود قابل للضبط (TDL) LGA-4500

محلل ليزر ديود قابل للضبط (TDL) LGA-4500

Utilizing proprietary technologies of Tunable Diode Laser Absorption Spectroscopy (TDLAS), FPI delivers the LGA system to satisfy in-situ measurements with high accuracy, fast response, strong reliability and virtually maintenance free.

FPI LGA system is applicable to almost all industrial process, especially well proven in harsh conditions in combination of high temperature, pressure, dust, corrosives and contaminants.

التنزيلات والموارد

احصل على عرض أسعار الآن
الوصف

نظرة عامة على المنتج

Utilizing proprietary technologies of Tunable Diode Laser Absorption Spectroscopy (TDLAS), FPI delivers the LGA system to satisfy in-situ measurements with high accuracy, fast response, strong reliability and virtually maintenance free.

FPI LGA system is applicable to almost all industrial process, especially well proven in harsh conditions in combination of high temperature, pressure, dust, corrosives and contaminants.

المبدأ

TDLAS technology utilizes the principle that laser energy is absorbed selectively by gas to form an absorption spectrum. Laserbeams of specific wavelengths is emitted by semiconductorlaser, and when passes through the gas, the attenuation of the laserintensity is related with measured gas. The concentration can beobtained by measuring intensity attenuation.

محلل ليزر ديود قابل للضبط (TDL) LGA-4500 المواصفات الفنيةh

 

Parameter Specification
Components O₂, CO, CO₂, H₂O, H₂S, HF, HCl, HCN, NH₃, CH₄, C₂H₂, C₂H₄, CH₃I
الدقة HF: 0.02ppm; HCl, NH₃, C₂H₂: 0.1ppm; H₂O, HCN: 0.3ppm; CH₄: 0.4ppm; C₂H₄, CH₃I: 0.6ppm; CO, CO₂: 10ppm; H₂S: 20ppm; O₂: 100ppm.
النطاق HF: (0~5)ppm; C₂H₂, NH₃: (0~10)ppm; HCN: (0~30)ppm; CH₃I: (0~40)ppm; HCl, H₂O: (0~50)ppm; C₂H₄, CH₄: (0~60)ppm; CO, CO₂: (0~1000)ppm; H₂S: (0~2000)ppm; O₂: (0~1)%Vol., customized
الخطية ≤±1%F.S.
انجراف الامتداد ≤±1%F.S./6 months
التكرار ≤±1%F.S.
وقت الاستجابة T₉₀≤20s (Flow rate more than 1 L/min)
Preheating Time ≤15min
درجة حرارة العمل -30~60°C
Storage Temperature -40~80°C
Purge Gas Instrument air, industrial N₂ (0.3~0.8)Mpa
Sample Pressure 0.5~3bar
Sample Temperature -30~250°C
Enclosing Rate IP65
Explosion-Proof Ex d IIC T5
مزود الطاقة 100~240V AC
Consumption ≤20W
Analog Inputs 2 way 4~20mA
Analog Outputs 2 way 4~20mA; isolation, maximum load 750Ω
Relay Outputs 3 way relays, 24V/1A

 

تطبيقات متعددة الاستخدامات في مختلف الصناعات

  • HCl, HF in waste incineration.
  • NH3 and HF monitoring in fertilizer plant.
  • HCl in pharma industry.
  • NH3 slip in thermal power plant SCR, SNCR.

الميزات الرئيسية ل محلل ليزر ديود قابل للضبط (TDL) LGA-4500

  • Monochromaticity with the spectral width down to 0.001nm ensures high precision and anti-interference from the background.
  • Maintenance-free with cross-stack alignment.
  • IECEx ex-proof suitable for adoption of the system in hazardous areas.
  • Auto drift correction extends calibration interval up to 1 year.

لماذا محلل ليزر ديود قابل للضبط (TDL) LGA-4500 تبرز

الأسئلة الشائعة

احصل على عرض أسعار الآن

فتح التحليل الدقيق مع محلل ليزر ديود قابل للضبط (TDL) LGA-4500

هل أنت مستعد لتحسين عملياتك باستخدام حلول التحليل عبر الإنترنت الرائدة في المجال؟ تواصل معنا للحصول على إرشادات الخبراء أو الأسعار أو عرض توضيحي مخصص.

المنتجات ذات الصلة

أرسل استفسارك اليوم

املأ النموذج أدناه، وسنتصل بك قريبًا.
معلومات الاتصال
تفاصيل المشروع