محلل ثاني أكسيد الكربون AQMS-400

FPI AQMS-400 carbon monoxide (CO) analyzer measures ambient CO concentration by employing nondispersive infrared with gas filter correlation method technology.

التنزيلات والموارد

احصل على عرض أسعار الآن
الوصف

نظرة عامة على المنتج

FPI AQMS-400 carbon monoxide (CO) analyzer measures ambient CO concentration by employing nondispersive infrared with gas filter correlation method technology.

المبدأ

Infrared energy emitted by light source is passed through gas chamber containing the air sample, and the quantitative absorption of energy by CO in the sample cell is measured by corresponding detector.

محلل ثاني أكسيد الكربون AQMS-400 المواصفات الفنيةh

Standard Range
Max:0~1000ppm Min:0~50ppm (Selectable)
المبدأ NDIR
صفر ضوضاء ≤0.02ppm (RMS)
ضوضاء الامتداد ≤0.25ppm (RMS)
Lower Detectable Limit ≤0.04ppm (RMS)
Display Digital
الانجراف الصفري <0.1ppm/24h
انجراف الامتداد ±0.5ppm/24h
الخطية <1%F.S.
Precision <1%
وقت الاستجابة T90<60s
Sample Flow Rate (800±80)sccm
Data Transmission 2 channel analog (4~20) mA;

12 digital input/output;

4-way relay output;

Communication RS232/RS485/Ethernet
درجة حرارة التشغيل US EPA Specification 20~30°C

Actual applicable:-5~55°C

Operating Humidity 0~95%RH
Calibration Multi-point calibrator
Power Requirement 220V AC/50Hz;

110V AC/60Hz

Dimensions and Weight 178(H)x432(W)x597(D)mm, 28kg

تطبيقات متعددة الاستخدامات في مختلف الصناعات

الميزات الرئيسية ل محلل ثاني أكسيد الكربون AQMS-400

  • 14 meters optical path to perform high reliability.
  • Five years guarantee on GFC wheel.
  • Compliance with US EPA reference method.
  • Various outputs include ethernet and RS232.
  • User friendly interface with large screen.
  • التشخيص المستمر للنظام مع التنبيه.
  • Multi-tasking software allows viewing test variables while operating;
  • Temperature and pressure compensation.
  • Internal data logging with 1 min to 365 day multiple averages.

GFC
GFC (Gas filter correlation) technology is utilized to remove interference caused by moisture and other backgrounds.

Two gas filled chambers are mounted on a rotating disc, which pass through an IR beam alternately. The measure chamber is filled with nitrogen while the reference chamber is filled with high concentration CO. IR beam then passes through the sample gas cell. The difference in absorbance is measured and provides a direct output of the gas concentration.

Data storage and analysis
Stored data are easily retrievable through the serial or ethernet port via PC client software, allowing operators to perform predictive diagnostics and enhanced data analysis by tracking parameter trends.

لماذا محلل ثاني أكسيد الكربون AQMS-400 تبرز

الأسئلة الشائعة

احصل على عرض أسعار الآن

فتح التحليل الدقيق مع محلل ثاني أكسيد الكربون AQMS-400

هل أنت مستعد لتحسين عملياتك باستخدام حلول التحليل عبر الإنترنت الرائدة في المجال؟ تواصل معنا للحصول على إرشادات الخبراء أو الأسعار أو عرض توضيحي مخصص.

المنتجات ذات الصلة

أرسل استفسارك اليوم

املأ النموذج أدناه، وسنتصل بك قريبًا.
معلومات الاتصال
تفاصيل المشروع