This monitor adopts the laser backscattering principle to measure the dust concentration. The embedded laser signasource traverses the flue and irradiates the dust particles. in this process, the irradiated dust particles will reflect laselsignals. And the detector can calculate the concentration of the dust based on a specific algorithm by detecting theintensity of the reflected laser signal.
| Measuring Type | In-situ |
| المبدأ | Laser backscattering |
| Flue Diameter | 0.8~20m |
| النطاق | 0~100mg/m³ to 0~2000mg/m³ (Customisable) |
| حد الاكتشاف الأدنى | 2mg/m³ |
| الانجراف الصفري | ≤±2%F.S./24h |
| انجراف الامتداد | ≤±2%F.S./24h |
| Precision | ≤±1%F.S. |
| وقت الاستجابة | ≤10s |
| درجة حرارة العمل | -20~+50℃ |
| Flue Temperature | 0~400℃ |
| استهلاك الطاقة | 24V DC 0.3A |
| Inst. Air | 100L/min |
| Alarm Output | Dry contact |
| Signal Output | 4~20mA, RS485 |
| Calibration Method | Manual |
| تصنيف الضميمة | IP66 |