الصفحة الرئيسية / المنتج / نظام المراقبة الإلكترونية للفورمالديهايد FMS-100

نظام المراقبة الإلكترونية للفورمالديهايد FMS-100

In recent years, mobile vehicle exhaust and industrial emissions of organic compounds VOCs are increasing, causing atmospheric photochemical smog pollution. Formaldehyde is highly reactive in the atmosphere, and it can generate HO2 radicals through photolysis, and HO2 radicals react rapidly with NO to generate OH radicals, so formaldehyde becomes an important source of atmospheric OH radicals.

التنزيلات والموارد

احصل على عرض أسعار الآن
الوصف

نظرة عامة على المنتج

In recent years, mobile vehicle exhaust and industrial emissions of organic compounds VOCs are increasing, causing atmospheric photochemical smog pollution. Formaldehyde is highly reactive in the atmosphere, and it can generate HO2 radicals through photolysis, and HO2 radicals react rapidly with NO to generate OH radicals, so formaldehyde becomes an important source of atmospheric OH radicals.

 

The FMS-100 detects formaldehyde in air based on the fluorometric method and the Hantzsch reaction principle. The reaction is carried out quantitatively. In the presence of ammonia, formaldehyde reacts with acetylacetone to produce 3,5-diacetyl-1,4-dihydropyridine (DDL), which is excited by UV and the concentration of formaldehyde is determined by monitoring the fluorescence intensity with a photomultiplier tube.

 

نظام المراقبة الإلكترونية للفورمالديهايد FMS-100 المواصفات الفنيةh

Detection Limit <50ppt
Measurement of Substances Formaldehyde in air and liquid
الدقة <10%
التكرار RSD<5%
النطاق 50ppt~3ppm
Linear Correlation Coefficient R>0.99
Absorption Efficiency 100%
Time Resolution Seconds/Minutes(Optional)

تطبيقات متعددة الاستخدامات في مختلف الصناعات

  • Formaldehyde concentration monitoring in ambient air.
  • Atmospheric photochemical smog pollution warning system.
  • Atmospheric environment complex pollution research.

الميزات الرئيسية ل نظام المراقبة الإلكترونية للفورمالديهايد FMS-100

  • Low detection limit, with a detection limit of <50ppt.
  • Absorption module with 100% capture efficiency for accurate monitoring for formaldehyde concentration.
  • It can achieve high-precision temperature control of each module of the system (±0.1°C) to ensure the accuracy of the measurement results.
  • Autonomous adjustment of the instrument’s time resolution at the second/minute level.
  • Visualization of formaldehyde concentration trends over time.
  • The gas-liquid separation adopts the unique flow path design to ensure real-time measurement results.

لماذا نظام المراقبة الإلكترونية للفورمالديهايد FMS-100 تبرز

الأسئلة الشائعة

احصل على عرض أسعار الآن

فتح التحليل الدقيق مع نظام المراقبة الإلكترونية للفورمالديهايد FMS-100

هل أنت مستعد لتحسين عملياتك باستخدام حلول التحليل عبر الإنترنت الرائدة في المجال؟ تواصل معنا للحصول على إرشادات الخبراء أو الأسعار أو عرض توضيحي مخصص.

المنتجات ذات الصلة

أرسل استفسارك اليوم

املأ النموذج أدناه، وسنتصل بك قريبًا.
معلومات الاتصال
تفاصيل المشروع