Sistema di monitoraggio online della formaldeide FMS-100

In recent years, mobile vehicle exhaust and industrial emissions of organic compounds VOCs are increasing, causing atmospheric photochemical smog pollution. Formaldehyde is highly reactive in the atmosphere, and it can generate HO2 radicals through photolysis, and HO2 radicals react rapidly with NO to generate OH radicals, so formaldehyde becomes an important source of atmospheric OH radicals.

Download e risorse

Richiedi subito un preventivo
Descrizione

Panoramica del prodotto

In recent years, mobile vehicle exhaust and industrial emissions of organic compounds VOCs are increasing, causing atmospheric photochemical smog pollution. Formaldehyde is highly reactive in the atmosphere, and it can generate HO2 radicals through photolysis, and HO2 radicals react rapidly with NO to generate OH radicals, so formaldehyde becomes an important source of atmospheric OH radicals.

 

The FMS-100 detects formaldehyde in air based on the fluorometric method and the Hantzsch reaction principle. The reaction is carried out quantitatively. In the presence of ammonia, formaldehyde reacts with acetylacetone to produce 3,5-diacetyl-1,4-dihydropyridine (DDL), which is excited by UV and the concentration of formaldehyde is determined by monitoring the fluorescence intensity with a photomultiplier tube.

 

Sistema di monitoraggio online della formaldeide FMS-100 Specifiche tecniche

Detection Limit <50ppt
Measurement of Substances Formaldehyde in air and liquid
Precisione <10%
Ripetibilità RSD<5%
Gamma 50ppt~3ppm
Linear Correlation Coefficient R>0.99
Absorption Efficiency 100%
Time Resolution Seconds/Minutes(Optional)

Applicazioni versatili in tutti i settori

  • Formaldehyde concentration monitoring in ambient air.
  • Atmospheric photochemical smog pollution warning system.
  • Atmospheric environment complex pollution research.

Caratteristiche principali di Sistema di monitoraggio online della formaldeide FMS-100

  • Low detection limit, with a detection limit of <50ppt.
  • Absorption module with 100% capture efficiency for accurate monitoring for formaldehyde concentration.
  • It can achieve high-precision temperature control of each module of the system (±0.1°C) to ensure the accuracy of the measurement results.
  • Autonomous adjustment of the instrument’s time resolution at the second/minute level.
  • Visualization of formaldehyde concentration trends over time.
  • The gas-liquid separation adopts the unique flow path design to ensure real-time measurement results.

Perché Sistema di monitoraggio online della formaldeide FMS-100 Si distingue

Domande frequenti

Richiedi subito un preventivo

Sbloccare l'analisi di precisione con Sistema di monitoraggio online della formaldeide FMS-100

Siete pronti a migliorare le vostre operazioni con soluzioni di analisi online leader del settore? Contattateci per ricevere una guida esperta, i prezzi o una demo personalizzata.

Prodotti correlati

Inviate oggi stesso la vostra richiesta

Compilate il modulo sottostante e vi contatteremo al più presto.
Informazioni di contatto
Dettagli del progetto