AQMS-450 CO2-Analysator

FPI AQMS-450 carbon dioxide (CO2) analyzer measures ambient CO2 concentration by employing Non-dispersive infrared (NDIR) with gas filter correlation (GFC) method technology to realize ppm level CO2 concentration measurement.

Downloads und Ressourcen

Jetzt ein Angebot einholen
Beschreibung

Produktübersicht

FPI AQMS-450 carbon dioxide (CO2) analyzer measures ambient CO2 concentration by employing Non-dispersive infrared (NDIR) with gas filter correlation (GFC) method technology to realize ppm level CO2 concentration measurement.

Principle
Infrared energy emitted by light source is passed through gas chamber containing the air sample, and the quantitative absorption of energy by CO in the sample cell is measured by corresponding detector.

GFC
GFC (Gas filter correlation) technology is utilized to remove interference caused by moisture and other backgrounds.
Two gas filled chambers are mounted on a rotating disc, which pass through an IR beam alternately. The measure chamber is filled with nitrogen while the reference chamber is filled with high concentration CO. IR beam then passes through the sample gas cell. The difference in absorbance is measured and provides a direct output of the gas concentration.

Data storage and analysis

Stored data are easily retrievable through the serial or ethernet port via PC client software, allowing operators to perform predictive diagnostics and enhanced data analysis by tracking parameter trends.

AQMS-450 CO2-Analysator Technische Daten

Standard Range

0~2000ppm

Zero Noise

≤0.1ppm

Span Noise

≤5ppm

Lower Detectable Limit

<0.2ppm

Precision

≤5ppm

Response Time

≤90s (T90)

Output

4~20mA,

RS232, RS485, Ethernet

Vielseitige Anwendungen in verschiedenen Branchen

Hauptmerkmale von AQMS-450 CO2-Analysator

  • The integrated purging device which eliminates the interference of environmental CO2 to the instrument measurement.
  • The White cavity design and special anti-corrosion technology on the surface of optical devices to give better stability and longer lifetime.
  • Wide measurement range with low detection limit, which can meet the needs of CO2 monitoring in most application.
  • Adopting GFC NDIR technology, measuring range is up to 2000 ppm.
  • High response, high repeatability, high accuracy and simple operation.
  • Support classified operation, automatically storing the calibration data and alarm information, etc.

Warum AQMS-450 CO2-Analysator Stellt sich heraus

Häufig gestellte Fragen

Jetzt ein Angebot einholen

Erschließen Sie die Präzisionsanalyse mit AQMS-450 CO2-Analysator

Sind Sie bereit, Ihre Abläufe mit branchenführenden Online-Analyselösungen zu verbessern? Setzen Sie sich mit uns in Verbindung, um fachkundige Beratung, Preise oder eine persönliche Demo zu erhalten.

Verwandte Produkte

Senden Sie Ihre Anfrage noch heute

Füllen Sie das nachstehende Formular aus, und wir werden uns in Kürze mit Ihnen in Verbindung setzen.
Kontaktinformationen
Details zum Projekt