Analisador de metais ambiente AMMS-100 XRF Especificações técnicas

Measuring Range 0~100μg/m³
Measuring Components (Optional) Al, Si, P, S, Cl, K, Ca, Sc, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Ga, As, Se, Br, Rb, Sr, Zr, Mo, Pd, Ag, Cd, In, Sn, Sb, Te, Cs, Ba, Au, Hg, Tl, Pb, and 38 other kinds of elements.
Lower Detection Level (Except Al) (0.01~10)ng/m³ (1 hour sampling)
Lower Detection Level of Al <40ng/m³
Other Elements Lower Detection Level P<5ng/m³, S<4ng/m³, Cr<1ng/m³, Si<8ng/m³, Pb<1ng/m³, As<1ng/m³, Cd<3ng/m³ (1 hour sampling)
Precision <1% (Pb standard film)
Linearity Pb, R>0.999
Repeatability of Internal Standard Substances <0.2%
Standard Film Accuracy <±2% (Pb standard film)

 

Particulate Matter

Measuring Range 0~1, 2, 5, 10mg/m³
Detection Limit 5μg/m³

 

Analyzer Running Indicators

Temperature Control Precision of X-ray Tube <±0.1℃
X-ray Tube Power <15W
Running Cycle 1 hour (default), optional
Sampling Flow Rate 4~20L/min adjustable, recommend 16.7L/min
Error of Sampling Flow <±2%
Tape Replacement Cycle 2 months (in 1 hour running cycle)
X-ray Tube Replacement Cycle >1 year
Cooling Built-in temperature control

Aplicações versáteis em todos os sectores

Principais caraterísticas de Analisador de metais ambiente AMMS-100 XRF

  • Measuring 30 toxic metals simultaneously.
  • Magnitude of detection limit 0.01-0.1 ng/mlevel.
  • Nondestructive test that the membrane sample can be preserved.
  • Associate measurements with the time of day or meteorological conditions make particular source tracing possible.
  • Continuous monitoring results in a large database that can conduct source modeling.
  • No consumable except filter tape replacement, no laboratory analysis. unattended online monitoring results in cost reduction and time-saving.

Porquê Analisador de metais ambiente AMMS-100 XRF Destaca-se

Perguntas mais frequentes

Obter um orçamento agora

Desbloquear a análise de precisão com Analisador de metais ambiente AMMS-100 XRF

Pronto para melhorar as suas operações com soluções de análise online líderes do sector? Entre em contacto para obter orientação especializada, preços ou uma demonstração personalizada.

Produtos relacionados

Envie hoje o seu pedido de informação

Preencha o formulário abaixo e entraremos em contacto em breve.
Informações de contacto
Detalhes do projeto