Início / Produto / Sistema de monitorização contínua das emissões CEMS-2000 (SO2 , NOX, CO, CO2)

Sistema de monitorização contínua das emissões CEMS-2000 (SO2 , NOX, CO, CO2)

FPI CEMS provides application gas analysis solution, integrated with Particulate Monitoring Subsystem, TPF Monitoring Subsystem, Gaseous (Pollutant) Monitoring Subsystem, Data Acquisition and Processing Subsystem, covering all the indicators and parameters to meet different customers’ needs. Such systems are extensively installed in industrial boilers, indicators and other emission sources with real-time data uploaded to local authorities.

Transferências e recursos

Obter um orçamento agora
Descrição

Visão geral do produto

FPI CEMS-2000 is a multi-gas monitoring system aimed to continuously and reliably measure emissions from various industrial combustions. The adoption of the hot-wet extractive method avoids the loss of content during sampling. The system is extendable with additional parameters upon request. All output signals proceed through the data acquisition system and then upload to the DCS or environmental authority server.

The system adopts a multi-gas analyzer to measure the concentration of SO₂, and NOx, by UV-DOAS method and concentration of CO and CO₂, by non-dispersive infrared (NDIR) module. The system also integrated internal maintenance and data process unit, which enables auto-calibration and online data transmission to minimize customer maintenance.

With decades of experience in CEMS research and development, FPI launched diverse and state-of-the-art analyzers which analyzers can be integrated into a complete continuous emission monitoring system. FPI can provide corresponding models for you to choose from below to meet different customers’ requirements for specific components monitoring.

Principle

CEMS-2000 continous emission monit-oring system adopts UV-DOAS technolgyDifferential Optical Absorption Spectroscopy (DOAS) is a kind ofspectrum monitortechnique. UV-DOAS can be defined as amethod ofdetermining gas concentrationby measuring specific narrow band abso-rption structures in the ultraviolet region.

Sistema de monitorização contínua das emissões CEMS-2000 (SO2 , NOX, CO, CO2) Especificações técnicas

Principles UV-DOAS & NDIR
Components SO2, NOX, O2, CO, CO2
Temperature (-20~50)℃
 

 

Range

SO2: 0~26~5000 ppm

NO/NOX:0~75~2000 ppm

O2: 0~25%

CO: 0~1250mg/m³

Detection Limit CO2: 0~20%
Linearity 1mg/m³
Span Drift ≤±1%F.S.
Zero Drift ≤±2%F.S./24h
Repeatability ≤±2%F.S./24h
Response Time ≤±1%
Power Supply UV-DOAS: ≤10s;  NDIR:≤30s
 

Output

220VAC; 50~60Hz

4~20mA, RS232, RS485

Aplicações versáteis em todos os sectores

  • Thermal Power Plant
  • Oil&Gas Industry
  • Cement Plant
  • Metallurgy Industry
  • Fertilizer Plant

Principais caraterísticas de Sistema de monitorização contínua das emissões CEMS-2000 (SO2 , NOX, CO, CO2)

  • UV-DOAS technology allows simultaneous measurement of multiple gases, with comparative a better signal-noise ratio over conventional technology;
  • The hot-wet extractive sampling system avoids condensation, corrosion and chalking;
  • Modular system design reduces the maintenance cost and gives a more stable system performance;
  • User-friendly interface and software provide a non-attended operation experience;

Porquê Sistema de monitorização contínua das emissões CEMS-2000 (SO2 , NOX, CO, CO2) Destaca-se

Perguntas mais frequentes

Obter um orçamento agora

Desbloquear a análise de precisão com Sistema de monitorização contínua das emissões CEMS-2000 (SO2 , NOX, CO, CO2)

Pronto para melhorar as suas operações com soluções de análise online líderes do sector? Entre em contacto para obter orientação especializada, preços ou uma demonstração personalizada.

Produtos relacionados

Envie hoje o seu pedido de informação

Preencha o formulário abaixo e entraremos em contacto em breve.
Informações de contacto
Detalhes do projeto