Inicio / Producto / Sistema de monitorización en línea de formaldehído FMS-100

Sistema de monitorización en línea de formaldehído FMS-100

In recent years, mobile vehicle exhaust and industrial emissions of organic compounds VOCs are increasing, causing atmospheric photochemical smog pollution. Formaldehyde is highly reactive in the atmosphere, and it can generate HO2 radicals through photolysis, and HO2 radicals react rapidly with NO to generate OH radicals, so formaldehyde becomes an important source of atmospheric OH radicals.

Descargas y recursos

Obtenga un presupuesto ahora
Descripción

Productos

In recent years, mobile vehicle exhaust and industrial emissions of organic compounds VOCs are increasing, causing atmospheric photochemical smog pollution. Formaldehyde is highly reactive in the atmosphere, and it can generate HO2 radicals through photolysis, and HO2 radicals react rapidly with NO to generate OH radicals, so formaldehyde becomes an important source of atmospheric OH radicals.

 

The FMS-100 detects formaldehyde in air based on the fluorometric method and the Hantzsch reaction principle. The reaction is carried out quantitatively. In the presence of ammonia, formaldehyde reacts with acetylacetone to produce 3,5-diacetyl-1,4-dihydropyridine (DDL), which is excited by UV and the concentration of formaldehyde is determined by monitoring the fluorescence intensity with a photomultiplier tube.

 

Sistema de monitorización en línea de formaldehído FMS-100 Especificaciones técnicas

Detection Limit <50ppt
Measurement of Substances Formaldehyde in air and liquid
Precisión <10%
Repeatability RSD<5%
Range 50ppt~3ppm
Linear Correlation Coefficient R>0.99
Absorption Efficiency 100%
Time Resolution Seconds/Minutes(Optional)

Aplicaciones versátiles en todos los sectores

  • Formaldehyde concentration monitoring in ambient air.
  • Atmospheric photochemical smog pollution warning system.
  • Atmospheric environment complex pollution research.

Características principales de Sistema de monitorización en línea de formaldehído FMS-100

  • Low detection limit, with a detection limit of <50ppt.
  • Absorption module with 100% capture efficiency for accurate monitoring for formaldehyde concentration.
  • It can achieve high-precision temperature control of each module of the system (±0.1°C) to ensure the accuracy of the measurement results.
  • Autonomous adjustment of the instrument’s time resolution at the second/minute level.
  • Visualization of formaldehyde concentration trends over time.
  • The gas-liquid separation adopts the unique flow path design to ensure real-time measurement results.

Por qué Sistema de monitorización en línea de formaldehído FMS-100 Destaca

Preguntas frecuentes

Obtenga un presupuesto ahora

Desbloquee el análisis de precisión con Sistema de monitorización en línea de formaldehído FMS-100

¿Está preparado para mejorar sus operaciones con soluciones de análisis en línea líderes en el sector? Póngase en contacto con nosotros para obtener asesoramiento experto, precios o una demostración personalizada.