FPI CEMS provides application gas analysis solution, integrated with Particulate Monitoring Subsystem, TPF Monitoring Subsystem, Gaseous (Pollutant) Monitoring Subsystem, Data Acquisition and Processing Subsystem, covering all the indicators and parameters to meet different customers’ needs. Such systems are extensively installed in industrial boilers, indicators and other emission sources with real-time data uploaded to local authorities.

Descargas y recursos

Obtenga un presupuesto ahora
Descripción

Productos

Mercury analyzer applies cold vapor atomic fluorescence technology (CVAFS), integrated with dilution sampling system to monitor the mercury presence in the stack in various forms. Automatic calibration of mercury check with internal CAL-200 calibration gas generator.

The system is extensively installed after desulfurization facility in coal-fired power plants and other fossil fuel boilers.The sample flue gas will be vaporized and analyzed in the optical cell without enrichment of particles, which gives a better response time. The CVAFS does not requires any adsorption and desorption on gold amalgam, which does not involve any loss of sample contents.

With decades of experience in CEMS research and development, FPI launched diverse and state-of-the-art analyzers which analyzers can be integrated into a complete continuous emission monitoring system. FPI can provide corresponding models for you to choose from below to meet different customers’ requirements for specific components monitoring.

Principio

CEMS-2000B Hg applies Dilution Extractive (40:1) & Cold Va-por Atomic Fluorescence Spectrometry (CVAFS) technologyThe mercury analyze emits an elementspecific spectrum, andthen measures the in-tensity of the emitted light to measurethe mercury concentration.

Sistema de monitorización de mercurio en línea CEMS-2000 B Hg Especificaciones técnicas

Principles Dilution extractive (40:1);
Cold Vapor Atomic Fluorescence (CVAFS)
Components Hg⁰, Hg²⁺, Hgᵀ
Temperatura (-20~50)°C
Range 0.1~20~500μg/m³
Detection Limit 0.05μg/m³
Linearity ≤±2%F.S
Span Drift ≤±2%F.S./24h
Zero Drift ≤±2%F.S./24h
Repeatability ≤2%
Response Time 180~360s
Power Supply 220VAC/50~60Hz
Output 4~20mA, RS232

Aplicaciones versátiles en todos los sectores

Características principales de Sistema de monitorización de mercurio en línea CEMS-2000 B Hg

  • High-performance thermal converter generates accurate measurement results for ionic mercury
  • Gas cell measurement without sample enrichment on gold amalgamation, fast data response and low maintenance cost
  • Dilution probe reduces the dew point to a low level, avoids sample condensation
  • Built-in nitrogen generator and mercury calibrator, no need of preparation of external consumables

Por qué Sistema de monitorización de mercurio en línea CEMS-2000 B Hg Destaca

Preguntas frecuentes

Obtenga un presupuesto ahora

Desbloquee el análisis de precisión con Sistema de monitorización de mercurio en línea CEMS-2000 B Hg

¿Está preparado para mejorar sus operaciones con soluciones de análisis en línea líderes en el sector? Póngase en contacto con nosotros para obtener asesoramiento experto, precios o una demostración personalizada.

Productos relacionados

Envíe su consulta hoy mismo

Rellene el siguiente formulario y en breve nos pondremos en contacto con usted.
Información de contacto
Detalles del proyecto