Inicio / Producto / CEMS-2000 D Sistema de monitorización de dilución de emisiones ultrabajas (SO2, NOx, H2O, O2)

CEMS-2000 D Sistema de monitorización de dilución de emisiones ultrabajas (SO2, NOx, H2O, O2)

FPI CEMS provides application gas analysis solution, integrated with Particulate Monitoring Subsystem, TPF Monitoring Subsystem, Gaseous (Pollutant) Monitoring Subsystem, Data Acquisition and Processing Subsystem, covering all the indicators and parameters to meet different customers’ needs. Such systems are extensively installed in industrial boilers, indicators and other emission sources with real-time data uploaded to local authorities.

Descargas y recursos

Obtenga un presupuesto ahora
Descripción

Productos

FPI CEMS-2000D is an automatic dilution extractive system ranging in dilution ratios from 20:1 to over 400:1, designed for SOx, NOx, O2, H2O, and meteorological parameters monitoring, ensuring consistent reliability, repeatability and precise measurement in the application of smelting, power generation, steel, and chemical.

The system consists of the dilution probe and multiple US EPA designated single gas analyzers, each gas analyzer works independently to enhance the detection limited ultimately.

With decades of experience in CEMS research and development, FPI launched diverse and state-of-the-art analyzers which analyzers can be integrated into a complete continuous emission monitoring system. FPI can provide corresponding models for you to choose from below to meet different customers’ requirements for specific components monitoring.

CEMS-2000 D Sistema de monitorización de dilución de emisiones ultrabajas (SO2, NOx, H2O, O2) Especificaciones técnicas

Range SO₂/NOx: Min.: (0~100) nmol/mol(ppb) Max.: (0~20) μmol/mol(ppm)
Detection Limit SO₂/NOx: 0.4 nmol/mol(ppb)
Linearity ≤1%F.S.
Span Drift(7 Days) ≤1%F.S.
Zero Drift(7 Days) <1 nmol/mol(ppb)
Repeatability ≤1%
Response Time NOx: <80 s to 95%
SO₂: <120 s to 90%
Sample Gas Flow Rate SO₂ analyzer: (650±65) sccm
NOx analyzer: (500±50) sccm
Working Temperature (5~40)°C
Working Humidity (0~95)% RH
Power Supply (200~240) V AC
Output 4~20mA, RS232, RS485, GPRS, Ethernet connection

Aplicaciones versátiles en todos los sectores

  • Thermal Power Plant
  • Cement Industry
  • Metallurgy Industry
  • Oil&Gas Industry

Características principales de CEMS-2000 D Sistema de monitorización de dilución de emisiones ultrabajas (SO2, NOx, H2O, O2)

  • US EPA designated trace level monitoring analyzers provide low-level detection possibilities.
  • Dilution probe reduces the dew point to a low level, avoids sample condensation.
  • Flexible analyzer and module combination to comply different industries.

Por qué CEMS-2000 D Sistema de monitorización de dilución de emisiones ultrabajas (SO2, NOx, H2O, O2) Destaca

Preguntas frecuentes

Obtenga un presupuesto ahora

Desbloquee el análisis de precisión con CEMS-2000 D Sistema de monitorización de dilución de emisiones ultrabajas (SO2, NOx, H2O, O2)

¿Está preparado para mejorar sus operaciones con soluciones de análisis en línea líderes en el sector? Póngase en contacto con nosotros para obtener asesoramiento experto, precios o una demostración personalizada.

Productos relacionados

Envíe su consulta hoy mismo

Rellene el siguiente formulario y en breve nos pondremos en contacto con usted.
Información de contacto
Detalles del proyecto